Something changed: the fan quietly died, a seal or membrane failed, or the house itself changed through renovation, new HVAC, or foundation work. Start at the manometer, then look at what is different since the last good test.
More detail
Work the list in order of likelihood. The fan first, because it is the moving part: level manometer fluid ends the investigation immediately. Seals second: sump lids lifted for pump service and never resealed, membrane seams pulled loose by stored boxes in a crawl, caulk joints that gave up. House changes third, and they are sneakier; a bathroom rough-in cut through the slab, a radon-oblivious waterproofing job that trenched the perimeter, an addition over a crawl the original design never covered, or a new high-draw range hood that shifted the pressure balance. Occasionally the ground itself shifts the equation after utility trenching or major grading nearby. Each cause has a proportionate fix, from a fan swap to an added suction point, and the diagnosis starts with a repair visit rather than a redesign. Retest after any fix to close the loop.