FAQ

How can I tell if my radon system is actually working?

Direct answer

Check the manometer on the pipe: the U-shaped gauge with colored fluid. Uneven fluid levels mean the fan is pulling; level fluid means it is not. Then confirm with a retest every two years, because the gauge proves suction, not room air.

More detail

The manometer is a pressure gauge, nothing more. When the fan runs, it holds the two fluid columns apart at roughly the reading marked at startup; compare against that mark, not against some universal number, because every system settles at its own pressure. Fluid that has gone flat means no suction: a dead fan, a tripped breaker, or an unplugged cord. Fluid that has drifted well off its mark in either direction is worth a call, since a big rise can mean a blocked pipe and a big drop can mean a membrane tear or a failing fan. Listen, too; a healthy fan is a low steady hum, and grinding or surging is bearings on their way out. Even a perfect gauge says nothing about the air you breathe, which is why the two-year retest stays on the calendar. The repair service handles everything the gauge can report.

Authoritative sources

Ready to get started?

El Paso County homes average 5. Mon-Sat 8am-6pm.