FAQ

My radon fan has gotten loud. What is happening?

Direct answer

A new grind or whine is usually bearings wearing out; a rattle is usually a mount or coupling loosening; a gurgle is condensation pooling in the pipe. None is an emergency, but a worn fan should be swapped before it quits silently.

More detail

Condensation noise deserves a Front Range note: warm, humid soil gas climbing a pipe through a subzero attic or up an exterior wall sheds water on the pipe walls, and a run with a sag or a too-flat slope collects it until the airstream bubbles through, the gurgle you hear at night. The cure is restoring pitch so water drains back to the suction point, not drilling a weep hole, which punctures the system. Vibration finds its way into framing when the rubber couplings that isolate the fan have aged stiff or a strap has loosened; a ten-dollar part, a ten-minute fix. Bearing noise only ever goes one direction, and a fan that has started to grind is months, not years, from stopping, after which the system protects nobody until someone notices the gauge. A repair visit sorts all three, and the fan swap itself is $200 to $650 installed.

Authoritative sources

Ready to get started?

El Paso County homes average 5. Mon-Sat 8am-6pm.

Call (719) 695-7610Text us

Prefer to text? Open your texting app